  • 1 KW Battery Chargers
  • 2 KW Battery Chargers
  • 1-5 KW Batery Chargers


Technology: Micro controller controlled MOSFET based SMPS technology




1 KW

Mechanical Detail
 
Input Range
 
Insulation Resistence
 
*230V AC,
*50Hz,
*184V - 265V
 
*Iput to Gnd :>1MΩ
*Output to Gnd :>1MΩ
*Input to out put:>1MΩ
 
Four Port Output
 
Port A
 
Port B
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation: < ±5 ‰
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation:<±5‰
 
Port C
 
Port D
 
*Voltage: 2V to 28.5V DC
*Current: 0 to 3Amps
*Mode of Charging: Constant Current
*Current regulation: Betterthan 10%
 
*Voltage: 2V to 28.5V DC
*Current: 0 to 1Amps
*Mode of Charging: Constant Current
*Current regulation:Betterthan 10%
 
Efficiency
 
*75% to 80%
 
LED Indicator Metering
 
*AC mains
*AC input low voltage
*AC input High Voltage
*Fan fail
*Out put ON for ports A & B
*Out put over load for ports A & B
*Reverse polarity
*CV/ CC Indications for Ports C & D
 
*3 digit DPM for Voltage display - common for all ports
*3 digit DPM for Current display - common for Ports A & B
*3 digit DPM for Current display - Ports C
*3 digit DPM for Current display - Ports D
 
Protections
 
*Input under voltage / over voltage
*Out put over load / Short CKT
*Out put reverse polarity
*Fan failure
*Fuse for AC Mains
*Independent AC Fuses for each port
 
Out put termination
 
*Heavy duty Banana terminals
 
Operating Temperature
 
*0 to 45 C
 
Altitude
 
*1000 m above MSL @
 
Relative Humidity
 
*90 to 95%
 
EMI / EMC
 
*Meets EMI / EMC specs as per UM-04, MIL-STD-461
 
Physical Dimensions Salient Features
 
*Length:400 mm
*Breadth:350 mm
*Height:285 mm
*Weight:<30 kgs
 
*Micro controller controlled intelligent charger
*Mosfet based SMPS technology
*Automatic volatge selection for ports C & D
*Float and boost modes for ports A & B
*Ruggedised design to withstand shock and vibration
 


Technology: Micro controller controlled MOSFET based SMPS technology




2 KW

Mechanical Detail
 
Input Range
 
Insulation Resistence
 
*230V AC,
*50Hz,
*184V - 265V
 
*Iput to Gnd :>1MΩ
*Output to Gnd :>1MΩ
*Input to out put:>1MΩ
 
Six Port Output
 
Port A
 
Port B
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation: < ±5 ‰
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation:<±5‰
 
Port C
 
Port D
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation: < ±5 ‰
 
*Voltage: 6V to 28.5V DC
*Current: 2A to 17.5A Max
*Mode of Charging: Constant Potential
*Voltage regulation:<±5‰
 
Port E
 
Port F
 
*Voltage: 2V to 28.5V DC
*Current: 0 to 3Amps
*Mode of Charging: Constant Current
*Current regulation: Betterthan 10%
 
*Voltage: 2V to 28.5V DC
*Current: 0 to 1Amps
*Mode of Charging: Constant Current
*Current regulation:Betterthan 10%
 
Efficiency
 
*75% to 80%
 
LED Indicator Metering
 
*AC mains
*AC input low voltage
*AC input High Voltage
*Fan fail
*Out put ON for ports A & B
*Out put over load for ports A & B
*Reverse polarity
*CV/ CC Indications for Ports C & D
 
*3 digit DPM for Voltage display - common for all ports
*3 digit DPM for Current display - common for Ports A & B
*3 digit DPM for Current display - Ports C
*3 digit DPM for Current display - Ports D
 
Controls Protections
 
*Power On through MCB
*Out put Voltage display selection band switch
*Toggle switch for current display selection of Port A & B
*Independent Start Switch for each Port
*Fuse for AC Mains
*Reset switch for ports C & D
*Independent Voltage set Potentiometer for each port
*Independent Current set Potentiometer for each port
*Auto/Manual selection switch for ports C & D
 
*Input under voltage / over voltage
*Out put over load / Short CKT
*Out put reverse polarity
*Fan failure
*Fuse for AC Mains
*Independent AC Fuses for each port
 
  Out put termination   Operating Temperature   Altitude
  *Heavy duty Banana terminals   *0 to 45 C   *1000 m above MSL @
 
  Relative Humidity   EMI / EMC
  *90 to 95%   *Meets EMI / EMC specs as per UM-04, MIL-STD-461
 
Physical Dimensions Salient Features
 
*Length:680 mm
*Breadth:500 mm
*Height:340 mm
*Weight:<50 kgs
 
*Micro controller controlled intelligent charger
*Mosfet based SMPS technology
*Automatic volatge selection for ports C & D
*Float and boost modes for ports A & B
*Ruggedised design to withstand shock and vibration
 


Technology: Micro controller controlled MOSFET based SMPS technology




1-5 KW
Mechanical Detail
  Input Range   Output   Efficiency
 
*230V AC,
*50Hz,
*184V - 265V
 
*Multi Ouput Options
 
*75 to 80%
 
  LED Indicator   Metering   EMI / EMC
  *For Status and Fault indication   *Digital Panel meters for Voltage and Current display   *Meets EMI / EMC specs as per UM-04, MIL-STD-461
 
Salient Features Other Features
 
*Micro controller controlled intelligent charger
*Mosfet based SMPS technology
*Automatic volatge selection for ports C & D
*Float and boost modes for ports A & B
*Ruggedised design to withstand shock and vibration
*Fully independent ports
*Uninterrupted charging of other ports incase any port fails
*Modular construction, can be extended to any power o/p
 
*Selectable ammeter ranges for better accuracy of current reading
*Our chargers meet environmental tests as per IS 9000
*Ergonomic and efficient smart controls with In Built Protections
 
 
 
Privacy Statement | Terms of use | Trade Marks